- Test 4 detectors at one time
- Easy 1 button operation
- Robust rechargeable internal battery, up to 1500 tests before recharging
- Internal gas cylinder regulator and pressure gauge
- USB flash memory for bump test and event log storage
- Optional detector configuration and firmware updates via GCT Manager Software
- Rugged case or Wall Mount Dock case
- No computer required to operate
Detector Configuration/Firmware Updates: In order to keep your fleet
of gas detectors compliant with specific settings, we allow for the MGC Pump Clip
Dock to program each detector during either bump testing or calibration. The
programmable fields are as follows: User ID, Calibration Interval, Bump
Interval, Self-Test Interval, Low Alarm, High Alarm, Show Sensor Readings, Hide
Bump Due LED and Hide Clock. For example, if your company or facility requires
each detector on site to have specific alarm set points and a bump test
interval, instead of programming each detector individually, the instruments can be
group programmed while simultaneously bump testing (4 detectors at a time per MGC
Pump Clip Dock) using our GCT Manager software. As firmware updates become available,
we can program each MGC Pump Dock to update detectors during bump testing and
calibration. Facility safety standard compliance for single gas detectors is now
easily achievable.
Event Data and Record Storage: In addition to performing tests,
detector configurations and firmware updates, the MGC Pump Dock also stores
important information about both the docking station and detectors tested. All tests
performed on the docking station can be accessed from either the USB directly or
using the GCT Manager software. Each bump test and calibration event is recorded
and logged by date, time and serial number. Along with the test records, the
individual event logs from each detector are saved. At the time of the test, the
detector transmits its’ event log to the memory. By default, the station will
save the previous 10 event logs.
MGC Pump Clip Dock Wall Mount: Gas Clip Technologies offers a wall mount
solution for our MGC Pump Clip Dock. Instead of being housed in a portable case, we
provide a slim cabinet type case that can be easily mounted on a wall. This
version is a perfect fit for facilities or office environments and is available
in a high pressure version.
Gas Clip Technologies GCT Manager software provides users the ability to
communicate and program the MGC Pump Clip Dock or MGC Pump Clip Dock Wall Mount via IR
Link or USB memory stick. In order to communicate with an MGC Pump Clip Dock system
via infrared, an IR Link is required. Following is a full list of programmable
features offered when communicating with the MGC Pump Clip Dock or MGC
Pump Clip Dock Wall Mount using the GCT Manager Software via the IR Link:
- Docking Station Location
- Number of Event Logs
- Auto Power-Off Time
- Gas Cylinder Expiration Date
- Gas Cylinder Lot #
- Gas Cylinder Concentration
- Feature Administration Controls
- Station Test Logs
- Individual Instrument Logs
- Inventory Report
- All IR Link Software
*System Requirements: Available for Windows© based PCs (XP,
Vista, Windows 7) ; Users must also install Microsoft Net 4.0 software.
Reviews