UPC Description
The Universal Pump Controller (UPC) is TXAM’s intermediate level pump controller. Modes of operation include QPD/LPD/GPD modes, an intricate temperature control mode, batch mode, and a basic timer mode.. The UPC is also used with the TXAM Multipoint system.
Additional features include a discreate input for pump inhibit/run, analog input, temperature probe, full Modbus RS 485 control/monitoring. The UUP is housed within a water-tight enclosure enduring protection form the elements and can be used in certain Class 1 Division 2 applications.
UPC Features
QPD/LPD/GPD
Batch Mode
Temperature Mode
Modbus RS 485
Multipoint
Pump Inhibit/ Run
UPC Specifications
Power
12v DC/120v AC input
12v DC/120v AC output
BLDC
Less than 1 AMP
Control Options
QPD / LPD / GPD
Batch Mode (Hourly/Daily)
Multi-Temp Control (4 Set-Points)
Cycles / Duration 1-10 / 1-6
Valve Board Control (VBC-Multipoint)
Pump Inhibit & Run
Input/Output
1x Dry Contact
1x Analog
RS485